Menentukan Drop tegangan pada Distribusi daya dari Generator ke motor Induksi tiga Fhasa disebabkan Panjang kabel penghantar unit screw press PTPN II Sawit Hulu
Keywords:
Voltage drop, conducting cable, cross-sectionalAbstract
Voltage drop is the amount of voltage lost in a conductor. The voltage drop on electric power lines is generally directly proportional to the length of the line and the load and inversely proportional to the cross-sectional area of the conductor. The magnitude of the voltage drop is expressed either in percent or in Volts. The analysis determines the voltage drop in the power distribution from the generator to the three-phase induction motor at PT. PERKEBUNAN NUSANTARA II Sawit Hulu uses 30 meters of copper conductor cable with a cross-sectional area of 400 mm2. This type of copper wire material with an absolute value of sending voltage of 389 volts and an absolute value of receiving voltage of 385 volts. So that there is a voltage drop based on the length of the conducting cable of 4 Volts. And if it is percentaged, the voltage drop value is 1.03%.
References
[1] Abdan Sakura. 2018 “ Rancang Bangun Generator Sebagai Sumber Energi Listrik Nanohidro. Fakultas
Matematika dan Ilmu Pengetahuan Alam, Universitas Lampung.
[2] Dedi Wardianto, Anrial 2022 “Analisis Kegagalan Mesin Screw Press (Failure Analysis of the Screw Press
Machine)”. Department of Mechanical Engineering, Institut Teknologi Padang.
[3] Drs. Yon Rijono. 2020. “Teknik Dasar Tenaga Listrik ” Dikutip Dari Buku Edisi Terbaru Yogyakarta.
[4] Hamdani, Arnawan Hasibuan 2019 "Analisi Pengaruh Jatuh Tegangan Terhadap Kerja Motor Induksi Tiga Fasa
Berbasis Matlab”. Jurnal Teknik Elektro Vol.1, No. 2, ISSN 2622-7002.
[5]Hasballah, T., & Siahaan, E.W.B. 2018 "Pengaruh Tekanan Screw Press Pada Proses Pengepresan Daging Buah
Menjadi Crude Palm Oil", Jurnal Darma Agung, XXVI, Vol. 1 hal. 722-729.
[6]Noorly Evalina, Abdul Azis H, Zulfikar. 2018 “Pengaturan Kecepatan Putaran Motor Induksi 3 Fasa
Menggunakan Programmable logic controller”. Staf Pengajar Jurusan Teknik Elektro Universitas
Muhammadiyah Sumatera Utara.
[7]Putu Pawitra Teguh Dharma, Suwarno. 2022 “Optimalisasi Kecepatan Putaran Motor Listrik Sebagai Beban Pada
PLTS 5 kWp’’ Kampus Pasca Sarjana Universitas Muhammadiyah Sumatera Utara.
[8]Zulfikar, Reihan. 2018 “Optimasi Penempatan Gardu Traksi Listrik Aliran Atas (LLA) Berdasarkan Drop Voltage
Untuk Meningkatkan Keandalan Pasokan Daya Listrik”. S1 Thesis, Universitas Pendidikan Indonesia.
[9]Zuraidah Tharo, Amani D. Tarigan. 2020 “Penggunaan Kapasitor Bank Sebagai Solusi Drop Tegangan Pada
Jaringan 20 KV’. Fakultas Sains & Teknologi,Universitas Pembangunan Pancabudi Medan.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Bayu Hillam Saputra Tambunan, ,

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.