Perhitungan Debit Koagulan Poly Aluminium Chloride (PAC) Yang Diinjeksikan Pada Air Baku Proses Pengolahan Air PT. X

Authors

  • Ratna Kristina Tarigan Teknik Kimia, Politeknik Teknologi Kimia Industri, Medan, Indonesia.

Keywords:

PAC, jar test, dosis, debit

Abstract

Poly Aluminum Chloride is a chemical used to reduce water turbidity. Poly Aluminum Chloride will agglomerate dirt in water into larger particles so that it settles more easily. The amount of coagulant added to the water must be precise so that the turbidity of the water can be suppressed to the maximum. To find out the optimal dose, a jar test procedure was carried out. The jar test was carried out by adding coagulants with different variations. The jar test will give results on how variations in the amount of coagulant affect the turbidity level of the water. In water with a turbidity of 25.2 NTU, the optimum dose of PAC coagulant used was 30 ppm. With this dose, the PAC coagulant discharge injected into raw water at a water treatment plant is 56,0747 ml/s.

References

[1] A. Budiman, C. Wahyudi, W. Irawati, And H. Hindarso, “Kinerja Koagulan Poly Aluminium Chloride (Pac) Dalam Penjernihan Air Sungai Kalimas Surabaya Menjadi Air Bersih,” Widya Teknik, Vol. 7, No. 1, Pp. 25–34, 2008.

[2] A. Nur, R. Anugrah, And Z. Farnas, “Op-023 Efektivitas Dan Efisiensi Koagulan Poly Aluminium

Chloride (Pac) Terhadap Performance Ipa Ktk Pdam Solok,” In Seminar Nasional Sains Dan Teknologi Lingkungan Ii, 2016, Pp. 128–131.

[3] D. Rizki Darmawan, M. Rangga Sururi, And E. Hartati, “Perencanaan Instalasi Pengolahan Air Minum Di Kecamatan Bandung Kidul, Kota Bandung,” Jurnal Serambi Engineering, Vol. Viii, No. 2, Pp. 5729–5738, 2023.

[4] I. D. A. Sutapa, “Optimalisasi Dosis Koagulan Aluminium Sulfat Dan Poli-Aluminium Klorida (Pac) Untuk Pengolahan Air Sungai Tanjung Dan Krueng Raya Optimalisation Of Aluminium Sulphate And Poly-Aluminium Chloride (Pac) To Treat Water From Tanjung And Kreung Raya Rivers,” Jurnal Kesehatan Masyarakat , Vol. 5, No. 5, Pp. 659–665, 2017.

[5] A. Barus, K. Tarigan, And P. Kemit, “Jurnal Rekayasa, Teknologi Proses Dan Sains Kimia Effect Of Al2o3

Levels On Poly Aluminium Chloride Added To The Water Purification Process At Tirtanadi Deli Tua,” Reprokimia, No. 27, Pp. 6–11, 2023.

[6] E. Maulana Wijayanto, A. Ulfah Farahdiba, And Dan Firra Rosariawari, “Penyisihan Total Suspended Solid (Tss) Air Sungai Dengan Hidraulis Koagulasi Flokulasi,” Jurnal Envirotek, Vol. 1, No. 2, Pp. 53–59, 2019.

[7] F. Andriani And Y. Hanani Darundiati, “Efektivitas Pac (Poly Aluminium Chloride) Dalam Menurunkan Kadar Fosfat Pada Limbah Cair Rumah Sakit Jiwa Prof. Dr. Soerojo Magelang,” Jurnal Kesehatan Masyarakat, Vol. 5, No. 5, Pp. 659–665, 2017, [Online]. Available:

Http://Ejournal3.Undip.Ac.Id/Index.Php/Jkm

[8] H. Darmadi, D. Kurnia, N. Nelza, And H. . Sempana, “Analisa Ukuran Rpm Agitator Pada Washing Getah Di Unit Tangki Pencucian Pada Factory Precleaning Pt. X”, Reprokimia, Vol. 1, No. 2, Pp. 10–18, Jan. 2023.

Published

2024-04-01

Issue

Section

Artikel Teknik Kimia

How to Cite

Kristina Tarigan, R. (2024). Perhitungan Debit Koagulan Poly Aluminium Chloride (PAC) Yang Diinjeksikan Pada Air Baku Proses Pengolahan Air PT. X. Jurnal Vokasi Teknik (JuVoTek), 2(1), 6-13. https://mentech.id/jurnal/index.php/juvotek/article/view/21

Similar Articles

11-18 of 18

You may also start an advanced similarity search for this article.